PRODUCTS & SOLUTIONS

  • 1
  • 2
  • 3
  • 4

FOAMWALL A2

Dimensions

width mm 1000

length upon request from continuous production process.

Thicknesses (S)

mm 25 -30 - 35 - 40 - 50 - 60 - 80 - 100 - 120 - 140 - 150 - 160 - 180 - 200 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities (max. mm 200).

Supports

galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).

Insulation through continuous foaming process

Polyurethane resins (PUR) and (not standard) polyisocianurate foams (PIR), density 39 ±2 Kg/m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) Initial value of thermal conductivity: λ = 0.020 W/(mK)

Protective treatments for external support available

On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films

Insights PIR foam

On request is available in PIR foam version (polyisocyanurate), a particular polymeric structure that guarantees excellent characteristics of fire behavior. The entire range of ISOLPACK panels has been certified in Class B-s2, d0 at CSTB (France) and at KIT (Germany) in compliance with UNI EN 13823 (SBI) * where, "B" expresses the quantity of heat produced during the first 600 seconds of the test <7.5 MJ (best value obtainable for foamed products); "S2" represents a very low development of the fumes and "d0" indicates the absolute absence of drops and/or inflamed particles. In last years, the SBI test has become a standard requirement in Europe for fire behavior of building materials. The new European standard for sandwich panels - UNI EN 14509 - uses the SBI system for fire classification purposes. ISOLPACK is the only one in Italy to design light, highly insulating applications with unequaled fire reaction requirements. In many cases it can replace the rock wool panel considering its fire reaction characteristics combined with the very high thermal insulation power.

EPD certification (CAM)

CAM available.
For more information on CAM certification, contact the technical / commercial department.

LOADS TABLE

PITCH BETWEEN SUPP.(m)
PANEL TICKNESS(mm)
SHEET TICKNESS(mm)
MATERIAL
MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
Panel
Thickness
(mm)
MaterialSheet
thickness
(mm)
Pitch 'L' in meters between the supports
1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
25ACCIAIO0,4 + 0,4
30ACCIAIO0,4 + 0,4 237 171 103 66 44 31 22 17 13 10
35ACCIAIO0,4 + 0,4 275 200 132 87 60 41 30 23 17 12
ALLUMINIO
40ACCIAIO0,4 + 0,4 317 238 163 107 74 52 38 29 22 17
ALLUMINIO
50ACCIAIO0,4 + 0,4 397 298 230 154 108 77 57 43 34 26
ALLUMINIO
60ACCIAIO0,4 + 0,4 477 358 286 206 146 106 79 60 47 37
ALLUMINIO
80ACCIAIO0,4 + 0,4 637 478 382 292 214 164 130 101 79 63
ALLUMINIO
100ACCIAIO0,4 + 0,4 709 531 425 354 268 205 162 131 109 91
ALLUMINIO
120ACCIAIO0,4 + 0,4 851 638 510 425 322 246 195 158 130 109
ALLUMINIO
140ACCIAIO0,4 + 0,4 993 745 596 496 376 288 227 184 152 128
150ACCIAIO0,4 + 0,4 1064 798 638 532 402 308 243 197 163 137
160ACCIAIO0,4 + 0,4 1135 851 681 568 429 329 260 210 174 146
180ACCIAIO0,4 + 0,4 1277 958 766 639 483 370 292 237 196 164
200ACCIAIO0,4 + 0,4 1420 1065 852 710 537 411 325 263 217 183
MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
Panel
Thickness
(mm)
MaterialSheet
thickness
(mm)
Pitch 'L' in meters between the supports
1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
25ACCIAIO0,4 + 0,4
30ACCIAIO0,4 + 0,420415112096684937282217
35ACCIAIO0,4 + 0,4240176140110896449382923
ALLUMINIO
40ACCIAIO0,4 + 0,42752031611341088060473629
ALLUMINIO
50ACCIAIO0,4 + 0,434625520216814311387685443
ALLUMINIO
60ACCIAIO0,4 + 0,4419308244202173137107867059
ALLUMINIO
80ACCIAIO0,4 + 0,45654153282712311851841169579
ALLUMINIO
100ACCIAIO0,4 + 0,4634465367303258225183146120100
ALLUMINIO
120ACCIAIO0,4 + 0,4767562442365311271223178145121
ALLUMINIO
140ACCIAIO0,4 + 0,4884654515428364317264210171142
150ACCIAIO0,4 + 0,4885655519430367320282226184153
160ACCIAIO0,4 + 0,4887656520431367321284243197164
180ACCIAIO0,4 + 0,4892658522435372325288246200170
200ACCIAIO0,4 + 0,4895661525438375328291247201171

TESTO PRE FOOTER ENG

EPD Certified Products

Criteri Ambientali Minimi (CAM)




Upon request, our PIR foam panels (only if produced with double metal support) and corrugated metal sheets can be provided with a CAM certificate.

AIPPEG General Conditions of Sale

General Catalogue RWPI Products

TECHNICAL AREA

This section is completely dedicated to the world of design and collects everything that interests designers who work in CAD. Through this section precious material is available for collection of construction details and installation of RWPI pre-insulated panels.

 

RWPI srl
Via Industria, 1
30029 San Stino di Livenza (VE)
 

Vat n°: 11446330018
 

© 2018-2021, RWPI srl. All rights reserved.